Send Message
products

HT Sensor 4-20ma Flush Diaphragm Pressure Sensor Oil Filled Pressure Sensor 9-36VDC

Basic Information
Place of Origin: Baoji,China
Brand Name: HT SENSOR
Certification: CE,RoHs,ISO9001
Model Number: BP93420-IIIQT2
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Standard Export Package
Delivery Time: 5-8 work days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 5000PCS/Month
Detail Information
Model NO.: BP93420-IIIQT2 Long-Term Stability: +-0.2%F.S/Year(Typ.)
Power Supply: 9-36VDC Ouptut: 4-20mA
Specification: Oil Filled Pressure Sensor Trademark: HTsensor
Origin: Baoji, China Measuring Medium: Liquid
Accuracy Grade: 0.5% Pressure Range: -100kpa...0kpa ~35kpa...3.5MPa
IP Rating: IP65 Customization: Available OEM And ODM
High Light:

4-20ma Flush Diaphragm Pressure Sensor

,

HT Sensor Flush Diaphragm Pressure Sensor

,

Oil Filled Pressure Sensor 9VDC


Product Description

BP93420-IIIQT2 HT SENSOR 4-20mA Flush Diaphragm Pressure Sensor transmitter

BP93420-IIIQT2 Pressure Transmitter


Introduction of flush diaphragm pressure sensor :
 

BP93420-IIIQT2 flushing diaphragm pressure sensor transducer adopts high precision cavity free measuring diaphragm, with a variety of characteristics of the amplifier circuit, such as wear resistance, high temperature resistance, etc., making this type suitable for a variety of working environments, coupled with the cavity free structure characteristics, especially suitable for measuring viscosity and slurry, cement and other granular fluid industrial pressure measurement occasions.

 

Performance Parameters of Flush Diaphragm Pressure Sensor
Measurement Range Flush Diaphragm Pressure Sensor -100kPa…0kPa ~ 35kPa…3.5MPa
Pressure Type of flush diaphragm pressure sensor transmitter Gauge Pressure, Absolute Pressure, Sealed Pressure
Overload ≤ 1.5 times of the rated range
Accuracy @ 25ºC ±0.25% (Typical) ±0.5% (Maximum)
Repeatability ≤0.1%FS
Hysteresis ≤0.1%FS
Long-Term Stability ±0.1%F.S/Year(Typical) ±0.2%F.S/Year(Maximum)
Zero Point Temperature Drift ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Full Scale Temperature Drift ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Frequency Response 2.4Khz
Compensation Temperature 0-70ºC(≤10mpa,customizable)
Operating Temperature -20ºC~80ºC
Storage Temperature -40ºC~120ºC
Vibration 10g,55Hz ~ 2kHz
Housing Material 304,316L
Diaphragm Material 316L
Insulation Resistance 100MΩ 100VDC
Explosion-proof Rating Ex db IIC T6 Gb
Protection Rating IP65
O-Ring Seal Fluoro rubber
Weight ~0.3kg


HT Sensor 4-20ma Flush Diaphragm Pressure Sensor Oil Filled Pressure Sensor 9-36VDC 0
HT Sensor 4-20ma Flush Diaphragm Pressure Sensor Oil Filled Pressure Sensor 9-36VDC 1HT Sensor 4-20ma Flush Diaphragm Pressure Sensor Oil Filled Pressure Sensor 9-36VDC 2

 

Product Features of flush diaphragm pressure sensor:

  • 1. Wide measurement range,Various pressure interface options
  • 2. Diverse output signal options
  • 3. Adjustable zero and full-scale
  • 4. High accuracy,multiple sterile process connections



Applications of flush diaphragm pressure sensor:

  • 1. Suitable for measuring non-corrosive gases and liquids with 316L
  • 2. Medical, biopharmaceutical, and food hygiene industries for sterile processing
  • 3. Used in the paper and chemical industries, as well as for sewage level and beverage can pressure measurements Suitable for hydraulic and pneumatic control systems
Output Signal oflush diaphragm pressure sensor Supply Voltage Output Type
4~20mA 12~30VDC 2/3/4 wire
0~10/20mA
3 wire
0/1~5V
0/1~10V
0.5~4.5V 5VDC
RS485 Communication Protocol 3.6~30V / Battery 4 wire
 
Hengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter


Hengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter




Hengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter

 
Ordering tips oflush diaphragm pressure sensor
  • 1. When selecting the product, please ensure that the medium to be measured is compatible with the contact parts of the product.
  • 2. When placing an order, please note that explosion-proof type products do not include digital display heads.
  • 3. When ordering transmitters with an LCD or LED display head, the power supply for the transmitter should not be lower than 20VDC.
  • 4. To ensure reliable operation of the product, it is recommended that users install lightning protection devices on-site and ensure that the product and power supply are  reliably grounded.
  • 5. The rated working temperature range of the Fluoro rubber O-ring is -20ºC to 250ºC. When the product's operating temperature is below -20ºC, it is necessary to choose an EPDM O-ring seal.
  • 6. The default cable length is 1.5m, available in three materials. If not specified, it will be supplied with polyethylene cable material. If you require a different cable material, please specify it in the order.
  • 7. For special requirements such as strong vibration, instantaneous impact force, strong electromagnetic or radio frequency interference, please inform our company and specify them in the order.
  
Order Guide of  flush diaphragm pressure sensor
BP93420XX Pressure Transmitter
  Code Outline Construction
IB General Pressure Transmitter IX Display Pressure Transmitter
IE Shock-resistant Aviation Pressure Transmitter IIC/III Industrial General/ Display Pressure Transmitter
IF Moisture-proof Pressure Transmitter IIE/IIIE General/Display Pressure Transmitter
IN Air Conditioning Dedicated Pressure Transmitter    
IC High-temperature Pressure Transmitter    
IQ/IQT Large Diaphragm /High-temperature Pressure Transmitter    
  Measurement Range -100kPa…0kPa ~ 35kPa…3.5MPa
(0-X)Kpa or MPa X: Indicates the Actual Measuring Range
  Code Power Supply
D1 24VDC
D2 5VDC
D3 Other
  Code Output Signal
S1 4~20mADC S5 0~20mADC
S2 1~5VDC S6 0~10VDC
S3 0~5VDC S7 0.5~4.5VDC
S4 0~10mADC    
  Code Pressure Connection
J1 M20×1.5
J2 G1/2
J3 G1/4
J4 7/16-20UNF
J5 Other
  Code Electrical Connection
B1 Hirschmann
B2 PG7 Plug
B3 Sealed Cable Output
B4 2088 Industrial Casing
B5 2088 Industrial Casing with Display
B6 Other
  Code Pressure Type
G Gauge Pressure
A Absolute Pressure
S Sealed Reference Pressure
Hengtong 4-20mA Sanitary Clamp Type Smart Pressure TransmitterHengtong 4-20mA Sanitary Clamp Type Smart Pressure Transmitter


FAQ of flush diaphragm pressure sensor:
 

Q1:Areyou manufactrade company?

A1:We are manufactrader with more than 29 years of experience.

 

Q2:Customized Product

A2:We provide OEM and Custom-Design services.

 

Q3:Quality Quarantee

A3:Our products have a limited 12 to 18 months warranty from shipment date to the original purchaser.Hengtong will replace or repair defective products free of charge.This warranty does not apply to any units have been modified,misused,neglected.

 

Q4:Shipment&packing

A4:Products are generally shipped by international Express including UPS,FedEx,DHL and INT for freight prepaid,also can use your shipment account to collect,Standard export packing,including inspection certification.

 

Q5:Contact US

A5:We have an active and experienced sales team to serve you on technical question and business issue.Just leave us message or click the Online Service.

 

HT Sensor 4-20ma Flush Diaphragm Pressure Sensor Oil Filled Pressure Sensor 9-36VDC 8


 
 

Contact Details
Lisa zhuang

Phone Number : +8618791975539

Whatsapp : +8618629200449