Place of Origin: | Baoji,China |
---|---|
Brand Name: | HT SENSOR |
Certification: | CE,RoHs,ISO9001 |
Model Number: | BP93420-IIIFL |
Minimum Order Quantity: | 1 |
Price: | Negotiable |
Packaging Details: | Standard Export Package |
Delivery Time: | 5-8 work days |
Payment Terms: | Western Union, L/C, T/T |
Supply Ability: | 5000PCS/Month |
Model NO.: | BP93420-IIIFL | Power Supply: | 9-36VDC |
---|---|---|---|
Ouptut: | 4-20mA With LCD LED Display | Pressure Type: | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Range: | 0-35kpa~20Mpa | Structure Type: | Flush Diaphragm Pressure Sensor |
Measuring Medium: | Liquid,gas ,Beverage Glue And So On | Accuracy Grade: | 0.5% |
IP Rating: | IP65 | Customization: | Available OEM And ODM |
High Light: | Flanged Flush Diaphragm Pressure Sensor,Flush Diaphragm Pressure Sensor DN25,Liquid Piezoresistive Pressure Transmitter |
Introduction of flush diaphragm pressure sensor:
The BP93420-III-FL pressure transmitter uses the HT series silicon resistive film oil-filled core as the signal measuring element. The process connection adopts direct welding of 316L isolation diaphragm and matching flange to ensure the precision of pressure measurement. The customized heat sink can adapt to high-temperature environments. The signal processing circuit located inside the stainless steel housing converts the sensor signal into a standard output signal. The entire product has undergone rigorous testing and aging screening of components, semi-finished products, and finished products, ensuring stable and reliable performance.
Performance Parameters | |
Measurement Range | -100kPa…0kPa ~ 35kPa…1MPa |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25℃ | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability& Hysteresis | 0.02%F.S(Typ.) 0.05%F.S(Max.) |
Long-Term Stability | ±0.1%F.S/Year(Typ.) ±0.2%F.S/Year(Max.) |
Zero Point Temperature Drift | ±0.02%F.S/℃(≤100KPa) ±0.01%F.S/℃(>100KPa) |
Full Scale Temperature Drift | ±0.02%F.S/℃(≤100KPa) ±0.01%F.S/℃(>100KPa) |
Frequency Response | 2.4Khz |
Compensation Temperature | 0-70℃(≤10mpa,customizable) |
Operating Temperature | -20℃~80℃ |
Storage Temperature | -40℃~120℃ |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Ex ia IIC T6 Ga |
Protection Rating | IP65 |
O-Ring Seal | Fluoro rubber |
Weight | ~4kg |
Product Features of flush diaphragm pressure sensor:
Applications of flush diaphragm pressure sensor:
Output Signal of flush diaphragm pressure sensor | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire |
|
0/1~5V | ||
0/1~10V | ||
0.5~4.5V | 5VDC | |
RS485 Communication Protocol | 3.6~30V / Battery | 4 wire |
Ordering tips of flush diaphragm pressure sensor |
Order Guide of flush diaphragm pressure sensor | ||||||||
BP93420XX | Pressure Transmitter | |||||||
Code | Outline Construction | |||||||
IB | General Pressure Transmitter | IX | Display Pressure Transmitter | |||||
IE | Shock-resistant Aviation Pressure Transmitter | IIC/III | Industrial General/ Display Pressure Transmitter | |||||
IF | Moisture-proof Pressure Transmitter | IIE/IIIE | General/Display Pressure Transmitter | |||||
IN | Air Conditioning Dedicated Pressure Transmitter | |||||||
IC | High-temperature Pressure Transmitter | |||||||
IQ/IQT | Large Diaphragm /High-temperature Pressure Transmitter | |||||||
Measurement Range | -100kPa…0kPa ~ 35kPa…3.5MPa | |||||||
(0-X)Kpa or MPa | X: Indicates the Actual Measuring Range | |||||||
Code | Power Supply | |||||||
D1 | 24VDC | |||||||
D2 | 5VDC | |||||||
D3 | Other | |||||||
Code | Output Signal | |||||||
S1 | 4~20mADC | S5 | 0~20mADC | |||||
S2 | 1~5VDC | S6 | 0~10VDC | |||||
S3 | 0~5VDC | S7 | 0.5~4.5VDC | |||||
S4 | 0~10mADC | |||||||
Code | Pressure Connection | |||||||
J1 | M20×1.5 | |||||||
J2 | G1/2 | |||||||
J3 | G1/4 | |||||||
J4 | 7/16-20UNF | |||||||
J5 | Other | |||||||
Code | Electrical Connection | |||||||
B1 | Hirschmann | |||||||
B2 | PG7 Plug | |||||||
B3 | Sealed Cable Output | |||||||
B4 | 2088 Industrial Casing | |||||||
B5 | 2088 Industrial Casing with Display | |||||||
B6 | Other | |||||||
Code | Pressure Type | |||||||
G | Gauge Pressure | |||||||
A | Absolute Pressure | |||||||
S | Sealed Reference Pressure |
FAQ of flush diaphragm pressure sensor:
1. Q: What are the features of your flush diaphragm pressure sensor transmitters?
A: High precision, durability, and excellent performance. Customization available.
2. Q: Can I customize special specifications?
A: Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service.
3. Q: What is your production capacity?
A: Our manufacturing facilities can produce up to 30,000 pressure sensor transmitters per month, so we are fully capable of meeting the needs of large-scale orders. However, it is advisable to contact our sales team in advance to ensure smooth production and delivery scheduling.
4. Q: What's the typical delivery period?
A: 5~8 working day for standard models. Customized products may vary.
5. Q: How are the products priced? Any discounts?
A: Competitive pricing with discounts for bulk orders or long-term partners.
6. Q: What is the warranty of your products? And after-sales service?
A: Our warranty time is 24 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.