Model No.: | BP9325 | Housing Material: | Stainless Steel |
---|---|---|---|
Operating Temperature: | -20℃ To +80℃ | Power Supply: | 10V/1.5mA |
Pressure Range: | 0-10kpa~60MPa | IP Rating: | IP65 |
Signal Output: | MV Signal | Connection Type: | With Cable |
Warranty: | 2 Years | Type: | Diffused Silicon Piezoresistive |
Highlight: | Silicon Piezoresistive Pressure Sensor,Hydraulic Control Silicon Piezoresistive Pressure Sensor,Pneumatic Control Silicon Piezoresistive Pressure Sensor |
Performance Parameters: | |||||
Measurement Range | Gauge(G) | 10KPa,20KPa,35KPa,100KPa,200KPa,350KPa,1000KPa,2000Kpa | |||
Absolute(A) | 100KPaA,200KPaA,350KPaA,700KPaA,1000KPaA,2000KPaA | ||||
Sealed (S) | 3500KPa,7MPa,10MPa,20MPa,40MPa,60MPa,100MPa | ||||
Typ | Max | Unit | |||
Linearity | ±0.15 | ±0.3 | %F.S | ||
Repeatability | 0.05 | 0.1 | %F.S | ||
Hysteresis | 0.05 | 0.1 | %F.S | ||
Zero Offset Output | 0±1 | 0±2 | mV | ||
Full Scale Output | ≤20KPa | 50±10 | 50±30 | mV | |
≥35kPa | 100±10 | 100±30 | mV | ||
Zero Offset Temp. Drift | ≤20KPa | ±1 | ±2 | %F.S | |
≥35kPa | ±0.5 | ±1 | %F.S | ||
Full Scale Temp. Drift | ≤20KPa | ±1 | ±2 | %F.S | |
≥35kPa | ±0.5 | ±1 | %F.S | ||
Compensated Temp. | ≤20KPa | 0~50 | ºC | ||
≥35kPa | 0~70 | ºC | |||
Operating Temperature | -20~80 | ºC | |||
Storage Temperature | -40~125 | ºC | |||
Allowable Overload | Take the smaller value between 3 times the full scale or 120MPa | ||||
Burst Pressure | 5X the full scale | ||||
Long-term Stability | 0.2 % | F.S/Year | |||
Diaphragm Material | 316L | ||||
Insulation Resistance | ≥200MΩ 100VDC | ||||
O-ring Seal | Nitrile rubber or Fluoro rubber | ||||
Vibration | No change under conditions of 10gRMS, 20Hz to 2000Hz | ||||
Shock | 100g,11ms | ||||
Response Time | ≤1ms | ||||
Filling Medium | Silicon Oil | ||||
Weight | ~0.2kg | ||||
The parameters are tested under the following conditions: Constant current of 1.5mA and ambient temperature of 25°C |
NOTE.:
1. During assembly, pay attention to the fit between the size of the sensing element and the transmitter housing to achieve the required air-tightness.
2. During assembly, ensure the sensor is aligned vertically and press it down evenly to prevent jamming or damaging the compensation plate.
3. The measured medium must be compatible with the material of the sensing element diaphragm and casing (316L). If not, special instructions should be provided when placing an order.
4. Do not use sharp objects to press the sensor diaphragm, as it may cause deformation or puncture of the diaphragm and damage the sensing element.
5. The pressure sensor's vent tube must be kept open to the atmosphere.
6. If there are changes in the pin leads, follow the label carried by the sensing element for accuracy.
FAQ:
1. Q: What are the features of your pressure sensor transmitters?
A: High precision, durability, and excellent performance. Customization available.
2. Q: Can I customize special specifications?
A: Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service.
3. Q: What is your production capacity?
A: Our manufacturing facilities can produce up to 30,000 pressure sensor transmitters per month, so we are fully capable of meeting the needs of large-scale orders. However, it is advisable to contact our sales team in advance to ensure smooth production and delivery scheduling.
4. Q: What's the typical delivery period?
A: 5~8 working day for standard models. Customized products may vary.
5. Q: How are the products priced? Any discounts?
A: Competitive pricing with discounts for bulk orders or long-term partners.
6. Q: What is the warranty of your products? And after-sales service?
A: Our warranty time is 24 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.