Place of Origin: | Baoji,China |
---|---|
Brand Name: | HT SENSOR |
Certification: | CE,RoHs,ISO9001 |
Model Number: | BPHT24-III |
Minimum Order Quantity: | 1 |
Price: | Negotiable |
Packaging Details: | Standard Export Package |
Delivery Time: | 5-8 work days |
Payment Terms: | Western Union, L/C, T/T |
Supply Ability: | 5000PCS/Month |
Model NO.: | BPHT24-III | Range: | 0-10kpa~35mpa |
---|---|---|---|
Protection Rating: | IP65 | Output: | 4-20mA Can With Hart |
Housing Material: | Aluminum Alloy | Pressure Type: | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Specification: | Flush Diaphragm Pressure Sensor Transmitter | Origin: | China |
Measuring Medium: | Liquid,gas ,Beverage Glue And So On | Accuracy Grade: | 0.5% |
High Light: | BPHT24-III Digital Pressure Transmitter,Digital Pressure Transmitter Flush Diaphragm,Flush Diaphragm Digital Pressure Sensors |
BPHT24-III Pressure Transmitter
Introduction of flush diaphragm pressure sensor transmitter:
BPHT24-III pressure transmitter is mainly used in the pressure measurement of viscous liquid mud anti-scaling and anti-crystallization oil shield machine. The whole adopts integrated stainless steel structure, and the two kinds of flat film structure with or without cavity can choose the material in contact with the medium is 316L stainless steel and fluorine rubber, which has good wear resistance and corrosion, good water resistance, strong anti-interference and good long-term stability. Easy to install., with high vibration resistance and impact resistance.
Product Features of flush diaphragm pressure sensor transmitter:
1. A variety of pressure interface options.
2. Designed for health applications to prevent moderate scale.
3. High precision, all stainless steel structure.
4. Easy to clean, adjustable and display.
Applications of flush diaphragm pressure sensor transmitter:
1. Suitable for 316L non-corrosive gas and liquid measurement.
2. Suitable for environmental protection and chemical industry.
3. Used in the Marine and aviation industries.
4. Ideal for use in medical, biopharmaceutical and food hygiene industries.
Performance Parameters of flush diaphragm pressure sensor transmitter | |
Measurement Range | 0~35Kpa…~20MPa |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25ºC | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability& Hysteresis | 0.02%F.S(Typ.) 0.05%F.S(Max.) |
Long-Term Stability | ±0.1%F.S/Year(Typ.) ±0.2%F.S/Year(Max.) |
Zero Point Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Full Scale Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Frequency Response | 2.4Khz |
Compensation Temperature | 0-70ºC(≤10mpa,customizable) |
Operating Temperature | -20ºC~80ºC |
Storage Temperature | -40ºC~120ºC |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Ex db IIC T6 Gb |
Protection Rating | IP65 |
O-Ring Seal | Fluoro rubber |
Weight | ~0.8kg |
Output Signal | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire |
|
0/1~5V | ||
0/1~10V | ||
0.5~4.5V | 5VDC | |
RS485 Communication Protocol | 3.6~30V / Battery | 4 wire |
Outline Construction | |
Dimension |
Ordering tips |
1. When choosing products, please make sure that medium compatible with contact part of the product being tested.
2. When placing an order, please note that explosion-proof products do not include a digital display.
3. When ordering with LCD or LED display head of transducer, transmitter power should not be less than 20 VDC.
4. To ensure the reliable operation of the product, it is recommended that the user in the field installation of lightning protection devices, and to ensure that products and power supply reliable grounding.
5. Fluorine rubber o-rings rated operating temperature range for - 20 ℃ ~ 250 ℃.When the product operating temperature is lower than -20℃, it is necessary to choose EPDM O-type seal ring.
6. The default cable length is 1.5m and there are three materials to choose from. If there are no special instructions, polyethylene cable materials can be used.If you require a different cable material, please indicate it in the order.
7. In case of special requirements such as strong vibration, instantaneous impact, strong electromagnetic or radio frequency interference, please inform us and indicate in the order.
Order Guide | ||||||||
BPHT24 | Pressure Transmitter | |||||||
Code | Outline Construction | |||||||
IX | Display Pressure Transmitter | IIC/III | Industrial General/ Display Pressure Transmitter | |||||
T | High-temperature resistant Pressure Transmitter | |||||||
Measurement Range | 0~35Kpa…~20MPa | |||||||
(0-X)Kpa or MPa | X: Indicates the Actual Measuring Range | |||||||
Code | Power Supply | |||||||
D1 | 24VDC | |||||||
D2 | 5VDC | |||||||
D3 | Other | |||||||
Code | Output Signal | |||||||
S1 | 4~20mADC | S5 | 0~20mADC | |||||
S2 | 1~5VDC | S6 | 0~10VDC | |||||
S3 | 0~5VDC | S7 | 0.5~4.5VDC | |||||
S4 | 0~10mADC | |||||||
Code | Pressure Connection | |||||||
J1 | M20×1.5 | |||||||
J2 | G1/2 | |||||||
J3 | G1/4 | |||||||
J4 | 7/16-20UNF | |||||||
J5 | Other | |||||||
Code | Electrical Connection | |||||||
B1 | Hirschmann | |||||||
B2 | PG7 Plug | |||||||
B3 | Sealed Cable Output | |||||||
B4 | 2088 Industrial Casing | |||||||
B5 | 2088 Industrial Casing with Display | |||||||
B6 | Other | |||||||
Code | Pressure Type | |||||||
G | Gauge Pressure | |||||||
A | Absolute Pressure | |||||||
S | Sealed Reference Pressure |