Product Details:
Payment & Shipping Terms:
|
Sensor: | Silicon Sensor | Output: | 133+/-33mV |
---|---|---|---|
Supply: | Less Than 2.0mA DC | Material: | SST 316L |
High Light: | underwater pressure sensor,water pressure transducer |
SMP2080 series OEM Stainless steel insulation film pressure sensor
Features
Measuring Range: -100kPa…0kPa~20kPa…70MPa
Imported chip, Laser trimming
SS 316L, Hastelloy C, titanium, tantalum and other materials for special applications.
φ19mm×15mm
OEM pressure sensor
● Application
Industrial process control
Gas, liquid and vapor pressure detection
Level measurement
Specification
Construction condition |
|
Diaphragm material |
SS 316L |
Housing material |
SS 316L |
Pin Wire |
Kovar/100mm silicone rubber wire |
Back pressure tube |
SS 316L (gauge and negative pressure only) |
Seal ring |
nitrile rubber |
Electrical Condition |
|
Power supply |
≤2.0 mA DC |
Impedance input |
2.5kΩ ~ 5 kΩ |
Impedance output |
2.5kΩ ~ 5 kΩ |
Response |
(10%~90%):<1ms |
Insulation resistance |
100MΩ,100V DC |
Overpressure |
2times FS, ( 0C/0B/0A/02 5times FS) |
Environment Condition |
|
Media applicability |
fluid which has no corrosion on stainless steel and nitrile rubber |
Shock |
No change at 10gRMS,(20~2000)Hz |
Impact |
100g,11ms |
Position |
Deviate 90° from any direction, zero change≤±0.05%FS |
Basic Condition |
|
Environment temperature |
(25±1)℃ |
Humidity |
(50%±10%)RH |
Atmospheric pressure |
(86~106) kPa |
Power supply |
(1.5±0.0015)mA DC |
● Outline construction (unit: mm)
Range<20MPa Range≥20MPa
Parameter (@1.5 Ma DC)
Item | Min. | Typ. | Max. | Units |
Linearity | ±0.1 | ±0.25 | %FS,BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Zero output | ±2.0 | mV DC | ||
FS output | 45 | 100 | mV DC | |
Compensated temp. range | 0~70 | ℃ | ||
Working temp. range | -40~125 | ℃ | ||
Storage temp. range | -55~150 | ℃ | ||
Zero temp. error | ±0.75 | ±1.0 | %FS @ 25℃ | |
Full temp. error | ±0.75 | ±1.0 | %FS @ 25℃ | |
Long term stability error | ±0.2 | %FS/year | ||
Note:1. The above performance indicators are tested under the benchmark conditions | ||||
2. The temperature range for temperature drift test is the compensation temperature range |
Contact Person: Allen
Tel: +8618092690661