Model: | BP101 | Medium Temperature: | -30 ~ 80 ℃ |
---|---|---|---|
Material: | Black Plastic | Weight: | About 0.02kg |
Measuring Medium: | Air | Ambient Temperature: | - 40-85 ℃ |
Customized Support: | OEM And ODM | Supply: | 5VDC |
Range: | 0-10kpa~200kpa | ||
High Light: | Industrial Differential Pressure Transmitter,Industrial Silicon Pressure Transmitter Sensor |
Air Test Silicon Differential Pressure Transmitter Sensor For Industrial
BP101 Silicon Piezoresistive Pressure Sensor
Introduction of Differential Pressure Transmitter :
BP101 silicon piezoresistive differential pressure sensor is a kind of diffused silicon element with high stability. It is a compact differential pressure sensor specially designed for small range differential pressure, which has a remarkable effect on small gas pressure measurement.It is known for its excellent reliability, repeatability and stability, making it ideal for accurate gas pressure measurement.
Product Features of Differential Pressure Transmitter :
Applications of Differential Pressure Transmitter :
Electrical performance of Differential Pressure Transmitter :
Performance Parameters | |
Measurement Range | 0-10KPa,0~~~200KPa |
Pressure Type | Differential Pressure |
Static pressure | 2 times of the rated range |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25℃ | ±0.5% (Typical), ±1% (Maximum) |
Zero Temperature Drift | ±2.5%F.S/℃(Typical) ±3%F.S/℃(Maximum) |
Span Temperature Drift | ±2.5%F.S/℃(Typical) ±3%F.S/℃(Maximum) |
Compensation Temperature | 0-50℃ |
Operating Temperature | -20℃~80℃ |
Storage Temperature | -40℃~100℃ |
Housing Material | Plastic |
Pressure connection | φ5 air nozzle or customizable |
Protection Rating | IP65 |
Ordering tips of Differential Pressure Transmitter
1. Pay attention to the fit between the core size and the transmitter housing during assembly to achieve the required airtightness
2. During the assembly of the housing, ensure it is aligned vertically and apply even pressure to avoid jamming or damaging the compensation plate.
3. If the measured medium is not compatible with the core diaphragm and the housing material (316L), special instructions should be provided when placing the order.
4. Avoid pressing the sensor diaphragm with hands or sharp objects to prevent damage to the core due to diaphragm deformation or piercing.
Q&A |